580x138xLOGO-CAPA.png.pagespeed.ic.0TTOfb2dnR580x138xLOGO-CAPA.png.pagespeed.ic.0TTOfb2dnR580x138xLOGO-CAPA.png.pagespeed.ic.0TTOfb2dnR580x138xLOGO-CAPA.png.pagespeed.ic.0TTOfb2dnR
  • Avisos
  • Destaques
    • Notícias e Eventos
    • Premiações
    • Calendário de Defesas
  • Ensino
    • Normas e Regulamentos
    • Formulários
    • Disciplinas
      • Catálogo
      • Oferta por Período
      • Instruções para Inscrição em Disciplinas
    • Áreas de Concentração
      • Estruturas e Materiais
      • Geotecnia
      • Mecânica Computacional
      • Petróleo, Gás e Energias Renováveis
      • Recursos Hídricos e Meio Ambiente
      • Sistemas Computacionais
    • Laboratórios
    • Calendário Acadêmico
  • Editais
    • Bolsas PEC
    • PDSE
    • PIPD
    • Capes-PrInt
    • Oportunidades de Bolsas
  • Links Úteis
  • Quem Somos
    • Equipe
    • Docentes
    • Ex-Docentes
    • Biblioteca
  • Acadêmicos
  • Publicações
    • Dissertações de Mestrado
    • Teses de Doutorado
  • Admissões
    • Mestrado
    • Doutorado
    • Pós-Doutorado
    • Docente
    • Sistema Selection
  • Contato
✕

ESTUDO DO COMPORTAMENTO DE UM SISTEMA DE LODOS ATIVADOS COM REATOR DE LEITO MÓVEL (MBBR)

Documento

  • Bibiana Karina Hernandes Izquierdo
    Baixar

Informações da Dissertação

Título

ESTUDO DO COMPORTAMENTO DE UM SISTEMA DE LODOS ATIVADOS COM REATOR DE LEITO MÓVEL (MBBR)

Autor

Bibiana Karina Hernándes Izquierdo

Resumo

O presente documento busca comparar a performance de um tratamento de Lodos Ativados convencional, operando sob condições típicas, com um Sistema de Lodos utilizando Leito Móvel, incrementando sua vazão 2.5 vezes a mais da utilizada no tratamento de Lodos Ativados convencional, no qual se obteve eficiência de remoção para DQO entre 88–93%, para DBO entre 88-94% e para SST entre 88-98%. O meio suporte usado nesta pesquisa é de forma cilíndrica, lisa na superfície e com divisões em sua parte interna. Suas dimensões são 23 mm de diâmetro e 25 mm de altura. A massa específica de cada meio suporte encontra-se entre 0,99 e 1,00 g/cm3, sua área é de 0,0222 m2 e área superficial ou de contacto equivalente a 443,50 m2/m3. O sistema foi instalado na unidade de lodos ativados do CETE/UFRJ, com vazão variável de 0,39 a 0,95 L/s, tendo operado por 13 meses. Com o uso desta tecnologia (MBBR) foi possível manter a mesma eficiência com aumento das vazões e com relações A/M crescentes desde 0,20 a 1,00 d-1. Pode-se concluir nesta pesquisa que mesmo com o crescimento da relação A/M aproximadamente de 5 vezes, e da vazão de 2,5 vezes, manteve-se a mesma eficiência, o que significa grande economia no dimensionamento do tanque de aeração.

Abstract

The present dissertation seeks to compare the performance of a standard Activated Sludge treatment, operating under typical conditions, with that of a Sludge System using Moving Bed, increasing the original flow rate up to 2.5 times that employed in the standard activated sludge treatment. The resulting removal efficiencies for COD ranged from 88 to 93%, that of BOD removal from 88 to 94%, and that of TSS from 88 to 98%. The engineered plastic media (carriers) adopted in this research are cylindrical, have smooth surfaces and are baffled inside. They are 23 mm long and 25 mm high. The density of each carrier lies between 0.99 and 1.00 g/cm3, its area is 0.0222 m2 and its surface area or equivalent contact area is 443.50 m2/m3. The system was set up in the activated sludge unity of CETE/UFRJ, with variable flow rate ranging from 0.39 to 0.95 L/s, and was in operation over 13 months. By using this technology (MBBR), it was possible to keep the same efficiency with increasing flow rates and increasing foodmicroorganism rates ranging from 0.20 to 1.00 day-1. It can be concluded, from the experimental results, that despite the approximately 5 times increase in the foodmicroorganism rate and the 2.5 increase in the flow rate, the same efficiency was kept, which means a substantial saving in the dimensioning of the aeration tank.

Ano

2006

Orientadores

José Paulo Soares de Azevedo | Eduardo Pacheco Jordão

Anexos

Logo-Simplificada-da-Coppe-Negativa-1-scaled

PEC

  • Quem Somos
    • Equipe
    • Docentes
    • Ex-Docentes
    • Biblioteca
  • Acadêmicos
  • Publicações
    • Dissertações de Mestrado
    • Teses de Doutorado
  • Admissões
    • Mestrado
    • Doutorado
    • Pós-Doutorado
    • Docente
    • Sistema Selection
  • Contato

Acadêmicos

  • Avisos
  • Destaques
    • Notícias e Eventos
    • Premiações
    • Calendário de Defesas
  • Ensino
    • Normas e Regulamentos
    • Formulários
    • Disciplinas
      • Catálogo
      • Oferta por Período
      • Instruções para Inscrição em Disciplinas
    • Áreas de Concentração
      • Estruturas e Materiais
      • Geotecnia
      • Mecânica Computacional
      • Petróleo, Gás e Energias Renováveis
      • Recursos Hídricos e Meio Ambiente
      • Sistemas Computacionais
    • Laboratórios
    • Calendário Acadêmico
  • Editais
    • Bolsas PEC
    • PDSE
    • PIPD
    • Capes-PrInt
    • Oportunidades de Bolsas
  • Links Úteis

Contato

Av. Athos da Silveira Ramos, 149 – Bloco B, Sala B-101 Cidade Universitária, Rio de Janeiro – RJ, 21941-909
(21) 3938-1569
academica@coc.ufrj.br

Todos os direitos reservados PROGRAMA DE ENGENHARIA CIVIL - COPPE/UFRJ © 2026

Desenvolvido por Digimaster Informática

  • Não há traduções disponíveis para esta página.