580x138xLOGO-CAPA.png.pagespeed.ic.0TTOfb2dnR580x138xLOGO-CAPA.png.pagespeed.ic.0TTOfb2dnR580x138xLOGO-CAPA.png.pagespeed.ic.0TTOfb2dnR580x138xLOGO-CAPA.png.pagespeed.ic.0TTOfb2dnR
  • Avisos
  • Destaques
    • Notícias e Eventos
    • Premiações
    • Calendário de Defesas
  • Ensino
    • Normas e Regulamentos
    • Formulários
    • Disciplinas
      • Catálogo
      • Oferta por Período
      • Instruções para Inscrição em Disciplinas
    • Áreas de Concentração
      • Estruturas e Materiais
      • Geotecnia
      • Mecânica Computacional
      • Petróleo, Gás e Energias Renováveis
      • Recursos Hídricos e Meio Ambiente
      • Sistemas Computacionais
    • Laboratórios
    • Calendário Acadêmico
  • Editais
    • Bolsas PEC
    • PDSE
    • PIPD
    • Capes-PrInt
    • Oportunidades de Bolsas
  • Links Úteis
  • Quem Somos
    • Equipe
    • Docentes
    • Ex-Docentes
    • Biblioteca
  • Acadêmicos
  • Publicações
    • Dissertações de Mestrado
    • Teses de Doutorado
  • Admissões
    • Mestrado
    • Doutorado
    • Pós-Doutorado
    • Docente
    • Sistema Selection
  • Contato
✕

ESTIMATIVA DE FLUXO DE CALOR SENSÍVEL COM SUPORTE DE CINTILOMETRIA – ESTUDO DE CASO: CIDADE UNIVERSITÁRIA – ILHA DO FUNDÃO/RJ

Documento

SAMPAIO_RJ_TM_17
Baixar

Informações da Dissertação

Título

ESTIMATIVA DE FLUXO DE CALOR SENSÍVEL COM SUPORTE DE CINTILOMETRIA – ESTUDO DE CASO: CIDADE UNIVERSITÁRIA - ILHA DO FUNDÃO/RJ

Autor

Rafael João Sampaio

Resumo

Os cintilômetros de larga abertura (CinLA) são aparelhos ópticos que estimam o fluxo de calor sensível (H) a partir de flutuações registradas na intensidade de luz de um feixe que se propaga entre um transmissor e um receptor. A presente dissertação propõe-se a estudar o comportamento da produção de calor sensível ao longo do dia na Cidade Universitária da Universidade Federal do Rio de Janeiro (UFRJ), campus da Ilha do Fundão/RJ, mediante o emprego de um CinLA. Em especial, analisa-se a sensibilidade do parâmetro de estrutura do índice refrativo ( Cn2) a variações na escala temporal de coleta e no que concerne a alterações na umidade e na temperatura do ar. Os dados foram coletados, ininterruptamente, no período entre 23 de setembro e 03 de outubro de 2016, com o cintilômetro instalado sobre o terraço de dois prédios no campus principal da UFRJ. Complementarmente, dados meteorológicos, fornecidos pela estação hidrometeorológica do IGEO/UFRJ, imagens do satélite GOES e cartas sinóticas foram utilizados para caracterizar a atmosfera local. Avaliações preliminares indicaram a opção por medições em intervalos de 5 minutos, obtidos a partir de subamostras coletadas a cada 30 segundos. Análise de sensibilidade mostrou que variações de até 10º C na temperatura podem alterar em até 8,8% os valores de H, enquanto que variações de ±10 hPa na pressão atmosférica provocaram alterações de 1,4% em H. No experimento conduzido, o maior valor de H encontrado foi 443,98 W.m-2 , e o valor médio foi de aproximadamente 64,38 W.m-2.

Abstract

The large aperture scintillometer (CinLA) is an optical device used to estimate averaged sensible heat fluxes (H) from fluctuations in the refractive index of the turbulent atmosphere in a light beam spread between a transmitter and a receiver. The present dissertation proposes to study the behavior of the sensible heat production during the day in the University City of the Federal University of Rio de Janeiro (UFRJ), campus of the Fundão Island / RJ, through the use of a CinLA. In particular, the sensitivity of the refractive index structure parameter (Cn2) to changes in the collection time scale and to changes in humidity and air temperature are analyzed. The data were collected, uninterruptedly, between September 23 and October 3, 2016, with the scintillometer installed on the terrace of two buildings on the main campus of UFRJ. In addition, meteorological data provided by the IGEO / UFRJ hydrometeorological station, images of the GOES satellite and synoptic charts were used to characterize the local atmosphere. Preliminary evaluations indicated the option of taking measurements at 5-minute intervals, obtained from subsamples collected every 30 seconds. Sensitivity analysis showed that variations of up to 10 ° C in temperature can alter H values up to 8,8%, while changes of ±10 hPa in atmospheric pressure can produce changes of 1,4% in H. In the experiment conducted, the highest value of H found was 443,98 W.m-2, and the mean value was approximately 64,38 W.m-2.

Ano

2017

Orientadores

Otto Corrêa Rotunno Filho | Afonso Augusto Magalhães de Araujo

Anexos

Logo-Simplificada-da-Coppe-Negativa-1-scaled

PEC

  • Quem Somos
    • Equipe
    • Docentes
    • Ex-Docentes
    • Biblioteca
  • Acadêmicos
  • Publicações
    • Dissertações de Mestrado
    • Teses de Doutorado
  • Admissões
    • Mestrado
    • Doutorado
    • Pós-Doutorado
    • Docente
    • Sistema Selection
  • Contato

Acadêmicos

  • Avisos
  • Destaques
    • Notícias e Eventos
    • Premiações
    • Calendário de Defesas
  • Ensino
    • Normas e Regulamentos
    • Formulários
    • Disciplinas
      • Catálogo
      • Oferta por Período
      • Instruções para Inscrição em Disciplinas
    • Áreas de Concentração
      • Estruturas e Materiais
      • Geotecnia
      • Mecânica Computacional
      • Petróleo, Gás e Energias Renováveis
      • Recursos Hídricos e Meio Ambiente
      • Sistemas Computacionais
    • Laboratórios
    • Calendário Acadêmico
  • Editais
    • Bolsas PEC
    • PDSE
    • PIPD
    • Capes-PrInt
    • Oportunidades de Bolsas
  • Links Úteis

Contato

Av. Athos da Silveira Ramos, 149 – Bloco B, Sala B-101 Cidade Universitária, Rio de Janeiro – RJ, 21941-909
(21) 3938-1569
academica@coc.ufrj.br

Todos os direitos reservados PROGRAMA DE ENGENHARIA CIVIL - COPPE/UFRJ © 2026

Desenvolvido por Digimaster Informática

  • Não há traduções disponíveis para esta página.