580x138xLOGO-CAPA.png.pagespeed.ic.0TTOfb2dnR580x138xLOGO-CAPA.png.pagespeed.ic.0TTOfb2dnR580x138xLOGO-CAPA.png.pagespeed.ic.0TTOfb2dnR580x138xLOGO-CAPA.png.pagespeed.ic.0TTOfb2dnR
  • Avisos
  • Destaques
    • Notícias e Eventos
    • Premiações
    • Calendário de Defesas
  • Ensino
    • Normas e Regulamentos
    • Formulários
    • Disciplinas
      • Catálogo
      • Oferta por Período
      • Instruções para Inscrição em Disciplinas
    • Áreas de Concentração
      • Estruturas e Materiais
      • Geotecnia
      • Mecânica Computacional
      • Petróleo, Gás e Energias Renováveis
      • Recursos Hídricos e Meio Ambiente
      • Sistemas Computacionais
    • Laboratórios
    • Calendário Acadêmico
  • Editais
    • Bolsas PEC
    • PDSE
    • PIPD
    • Capes-PrInt
    • Oportunidades de Bolsas
  • Links Úteis
  • Quem Somos
    • Equipe
    • Docentes
    • Ex-Docentes
    • Biblioteca
  • Acadêmicos
  • Publicações
    • Dissertações de Mestrado
    • Teses de Doutorado
  • Admissões
    • Mestrado
    • Doutorado
    • Pós-Doutorado
    • Docente
    • Sistema Selection
  • Contato
✕

AÇÃO DE VENTO DOWNBURST EM TORRES DE LINHAS DE TRANSMISSÃO

Documento

  • Luiz Fernando Marcelino Gomes, Msc, 2025
    Baixar

Informações da Dissertação

Título

AÇÃO DE VENTO DOWNBURST EM TORRES DE LINHAS DE TRANSMISSÃO

Autor

Luiz Fernando Marcelino Gomes

Resumo

Os downbursts são fenômenos originados de tormentas elétricas (TS) e caracterizados por uma corrente descendente de ar que, ao se chocar com o solo, produz ventos divergentes de alta intensidade. No Brasil, os ventos extremos são produzidos por downbursts e por ciclones extratropicais. Entretanto, a maior parte dos códigos e normas de projeto orientados para as ações do vento nas estruturas se baseia nas características do vento de ciclones extratropicais, caracterizado como vento sinótico. As linhas de transmissão, por sua grande extensão horizontal, apresentam alta probabilidade de serem atingidas por fenômenos locais como downbursts e a carência de um modelo de cálculo previsto em norma para essas ações aumenta a incerteza sobre a margem de segurança dessas estruturas. O presente estudo compara a modelagem das forças aerodinâmicas de ventos TS e sinótico e a resposta estrutural de um modelo numérico do sistema acoplado torres, linhas aéreas e bielas de um trecho de linha de transmissão (LT). Para o cálculo das forças aerodinâmicas originadas do vento TS adota-se um modelo analítico e uma proposta de modelo simplificado da literatura, focalizando a distribuição das forças ao longo da LT e para o vento sinótico, um procedimento normativo. Conclui-se, com os modelos adotados e admitido o mesmo valor de velocidade básica do vento, que a ação do vento TS é mais desfavorável do que a do vento sinótico. Além disso, os resultados apontam para uma revisão nas dimensões representativas da atuação do vento TS na citada proposta da literatura.

Abstract

Downburst is a strong downward flow usually associated with a thunderstorm (TS) that, upon hitting the ground, produces divergent high-intensity winds. In Brazil, extreme winds are generally produced by downbursts and extratropical cyclones. However, most design codes and standards for wind actions on structures are based on the characteristics of extratropical cyclone winds, also known as synoptic winds. Due to their great horizontal extension, transmission lines have a high probability of being hit by local phenomena such as downbursts, and the lack of a calculation model provided in standards for these actions increases the uncertainty on the safety margin of these structures design. The present study compares the modeling of aerodynamic forces from TS and synoptic winds and the structural response of a numerical model of the coupled system of towers, conductors and insulation chains of a transmission line (TL) portion. For the calculation of the aerodynamic forces originating from the TS wind, an analytical model and a simplified model proposal from the literature are adopted, focusing on the distribution of forces along the TL, and for the synoptic wind, a design code procedure is applied. It is concluded, with the adopted models and assuming the same basic wind speed value, that the action of the TS wind is more unfavorable than that of the synoptic wind. Furthermore, the results point to a revision in the representative dimensions of the TS wind's action in the aforementioned proposal from the literature.

Ano

2025

Orientadores

Michèle Schubert Pfeil | Ronaldo Carvalho Battista

Anexos

Logo-Simplificada-da-Coppe-Negativa-1-scaled

PEC

  • Quem Somos
    • Equipe
    • Docentes
    • Ex-Docentes
    • Biblioteca
  • Acadêmicos
  • Publicações
    • Dissertações de Mestrado
    • Teses de Doutorado
  • Admissões
    • Mestrado
    • Doutorado
    • Pós-Doutorado
    • Docente
    • Sistema Selection
  • Contato

Acadêmicos

  • Avisos
  • Destaques
    • Notícias e Eventos
    • Premiações
    • Calendário de Defesas
  • Ensino
    • Normas e Regulamentos
    • Formulários
    • Disciplinas
      • Catálogo
      • Oferta por Período
      • Instruções para Inscrição em Disciplinas
    • Áreas de Concentração
      • Estruturas e Materiais
      • Geotecnia
      • Mecânica Computacional
      • Petróleo, Gás e Energias Renováveis
      • Recursos Hídricos e Meio Ambiente
      • Sistemas Computacionais
    • Laboratórios
    • Calendário Acadêmico
  • Editais
    • Bolsas PEC
    • PDSE
    • PIPD
    • Capes-PrInt
    • Oportunidades de Bolsas
  • Links Úteis

Contato

Av. Athos da Silveira Ramos, 149 – Bloco B, Sala B-101 Cidade Universitária, Rio de Janeiro – RJ, 21941-909
(21) 3938-7390
academica@coc.ufrj.br

Todos os direitos reservados PROGRAMA DE ENGENHARIA CIVIL - COPPE/UFRJ © 2026

Desenvolvido por Digimaster Informática

  • Não há traduções disponíveis para esta página.